 1/6
TR0636E-20027
IT3D(M)-300S-BGA (57) BGA Shearing Force TEST REPORT
APPROVED CHECKED PREPARED
TY. ARAI TM.MATSUO TY.TAKADA
HIROSE ELECTRIC CO., LTD.
2/6
[1] Objective
To evaluate BGA shearing force by comparing Initial state and Post 3500 thermal cycle in accordance with IPC-9701.
[2] Specimens
Type Type_1 Type_2 Type_3 Type_4 Product IT3D-300S-BGA (57) IT3D-300S-BGA (57) IT3D-300S-BGA (57) IT3D-300S-BGA (57) Assembly Virgin Reworked Virgin Reworked State Initial Initial Post 3500 cycles Post 3500 cycles 3 # of specimens 3 3 3
Remarks
*Type_3, Type_4 are assembled as Fig.1. *The test board design is based on IPC-9701 specification. *Thickness of the PCB: 3.3mm
Fig.1 [3] Test period
From: To : 2007-09-12 2008-01-18
[4] Test Equipment
Test equipment
Insertion and withdrawal force tester
Model
AG-IS
Manufacture
Shimazu
3/6
BGA shearing force
1. Requirements
The failure mode for the sheared balls shall be either bulk solder failure or copper pad lift-off. Intermetallic failure is unacceptable.
2.
Conditions
2-1 Test Condition
0
(+10 / 0 C ) ( 0 / -100C )
Test cycle : 3500 cycles
2-2 BGA Shearing Force
IT3D-300S-BGA(57) CONNECTOR Sample * Speed: 500 micrometer /second
Insertion and withdrawal force tester
0.3mm space Test PCB
4/6
4.
Results
4-1 BGA Shearing Force
UNIT: KN No. State Assembly 1 2 3 MAX MIN AVG Virgin 1.22 1.18 1.25 1.25 1.18 1.22 Type-1 Initial Reworked 1.18 1.16 1.18 1.18 1.16 1.17 Type-2 Type-3 Type-4
Post 3500 thermal cycles Virgin 1.21 1.13 1.13 1.21 1.13 1.16 Reworked 1.13 0.91 1.11 1.13 0.91 1.05
4-2
Failure Mode No intermetallic failure was found in all specimens. Copper pad lift-off was found in the sheared area. Details are shown in the following pages.
5/6
Type-1 (Initial)
Virgin
Copper Pad lift-off
Type-2 (Initial)
Reworked
Copper Pad lift-off
6/6
Type-3 (Post 3500 thermal cycles)
Virgin
Copper Pad lift-off
Type-4 (Post 3500 thermal cycles)
Reworked
Copper Pad lift-off


▲Up To Search▲   

 
Price & Availability of IT3D-300S-BGA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X